Residue on 600micron IS sieve (%by mass)

Tests on Emulsion

Residue on 600micron IS sieve (%by mass)

Code: This test is done as per IS: 8887-2004

Procedure:

  • i) Wash the sieve with xylene and then with acetone. Place it in the dish, dry in the oven at 100 to 110°C for 1 hour, cool and weigh, together with the dish, to the nearest 0.01 g (W1).
  • ii) Remove the sieve from the dish and moisten with the solution. Remove uniformly the 4-litre sample by gentle agitation and strain immediately through the sieve into the clean, dry, weighed container (W4).
  • iii) Sieve the low and high viscosity emulsion at room temperature and 50°C respectively. When whole of the emulsion has been passed through the sieve, remove the sieve and weigh the container to the nearest 1g (W2).
  • iv) Wash the sieve repeatedly with distilled water until the washings run clear. Place the sieve in the small dish to dry for 2 hrs in the oven at 105 ±5°C, Cool and reweigh together to the nearest 0.01 g (W3).

Uses:

Used to determine the Residue present in the Emulsion.